CyberKnife System [Target Tracking/Motion Management]: Pre-Treatment Imaging, Image Fusion and Treatment Planning Technique

Authors

  • Fuqdan Abd Al-Yamh karim, Zaianb Hammeed Kadum, Raysan Naeem Layyad Al-Hilla University College, Department of Medical Physics, Iraq

Keywords:

CyberKnife System, Motion Management, Treatment Imaging, Image Fusion

Abstract

In order to control motion, the CyberKnife uses continuous X-ray and optic image guiding to send out a plethora of precisely targeted, non-coplanar radiation beams. The delivery of stereotactic body radiation therapy has been greatly improved by this method, which allows for the focused delivery of tumour dose while sparing surrounding normal tissue. Covering topics such as pretreatment patient setup, treatment planning, and treatment delivery, this chapter gives an overview of the CyberKnife system from the perspective of a particular institution. It also covers capabilities like as target monitoring and motion management. The original idea of the CyberKnife was to create a more advanced focused stereotactic radiosurgery technology. Many technical advancements have been made to the CyberKnife since its developer, Dr. John Adler, treated the first patient with it in 1994 at Stanford University Medical Centre. Technical advancements have made it possible to treat tumours in different places, including tumours that migrate, expanding the original treatment window from brain tumours to other types of tumours.

Downloads

Download data is not yet available.

References

Collins BT, Vahdat S, Erickson K, Collins SP, Suy S, Yu X, Zhang Y, Subramaniam D, Reichner CA,Sarikaya I, Esposito G, Yousefi S, Jamis-Dow C, Banovac F, Anderson ED (2009) Radical Cyberkniferadiosurgery with tumor tracking: an effective treatment for inoperable small peripheral stage I non-small celllung cancer. J Hematol Oncol 2:1

Coon D, Gokhale AS, Burton SA, Heron DE, Ozhasoglu C, Christie N (2008) Fractionated stereotactic bodyradiation therapy in the treatment of primary, recurrent, and metastatic lung tumors: the role of positronemission tomography/computed tomography-based treatment planning. Clin Lung Cancer 9:217–221

Echner GG, Kilby W, Lee M, Earnst E, Sayeh S, Schlaefer A, Rhein B, Dooley JR, Lang C, Blanck O,Lessard E, Maurer CR Jr, Schlegel W (2009) The design, physical properties and clinical utility of an iriscollimator for robotic radiosurgery. Phys Med Biol 54:5359–5380

Freeman DE, King CR (2011) Stereotactic body radiotherapy for low-risk prostate cancer: five-yearoutcomes. Radiat Oncol 6:3

Friedland JL, Freeman DE, Masterson-Mcgary ME, Spellberg DM (2009) Stereotactic body radiotherapy: anemerging treatment approach for localized prostate cancer. Technol Cancer Res Treat 8:387–392

Ho AK, Fu D, Cotrutz C, Hancock SL, Chang SD, Gibbs IC, Maurer CR Jr, Adler JR Jr (2007) A study of theaccuracy of Cyberknife spinal radiosurgery using skeletal structure tracking. Neurosurgery 60:147–156

Hong JC, Yu Y, Rao AK, Dieterich S, Maxim PG, Le QT, Diehn M, Sze DY, Kothary N, Loo BW Jr (2011)High retention and safety of percutaneously implanted endovascular embolization coils as fiducial markers forimageguided stereotactic ablative radiotherapy of pulmonary tumors. Int J Radiat Oncol Biol Phys 81:85–90

Hoogeman M, Prevost JB, Nuyttens J, Poll J, Levendag P, Heijmen B (2009b) Clinical accuracy of therespiratory tumor tracking system of the cyberknife: assessment by analysis of log files. Int J Radiat OncolBiol Phys 74: 297–303

Jabbari S, Weinberg VK, Kaprealian T, Hsu IC, Ma L, Chuang C, Descovich M, Shiao S, Shinohara K, RoachM III, Gottschalk AR (2011) Stereotactic body radiotherapy as monotherapy or post-external beamradiotherapy boost for prostate cancer: technique, early toxicity, and PSA response. Int J Radiat Oncol BiolPhys 56:7767–7775

Katz AJ, Santoro M, Ashley R, Diblasio F, Witten M (2010) Stereotactic body radiotherapy for organ-confined prostate cancer. BMC Urol 10:1

Kilby W, Dooley JR, Kuduvalli G, Sayeh S, Maurer CR Jr (2010) The CyberKnife robotic radiosurgerysystem in 2010. Technol Cancer Res Treat 9:433–452

King CR, Brooks JD, Gill H, Pawlicki T, Cotrutz C, Presti JC Jr (2009) Stereotactic body radiotherapy forlocalized prostate cancer: interim results of a prospective phase II clinical trial. Int J Radiat Oncol Biol Phys73:1043–1048

Lanciano R, Lamond J, Yang J, Feng J, Arrigo S, Good M, Brady L (2011) Stereotactic body radiationtherapy for patients with heavily pretreated liver metastases and liver tumors. Int J Radiat Oncol Biol Phys81:s354

Louis C, Dewas S, Mirabel X, Lacornerie T, Adenis A, Bonodeau F, Lartigau E (2010) Stereotacticradiotherapy of hepatocellular carcinoma: preliminary results. Technol Cancer Res Treat 9:479–487

Mahadevan A, Miksad R, Goldstein M, Sullivan R, Bullock A, Buchbinder E, Pleskow D, Sawhney M, KentT, Vollmer C, Callery M (2011) Induction Gemcitabine and stereotactic body radiotherapy for locallyadvanced nonmetastatic pancreas cancer. Int J Radiat Oncol Biol Phys 81:e615–e622

Mardirossian G, Muniruzaman M, Lee C, Jin H (2009) Validation of accuracy Multiplan Monte Carlotreatment plans. In: CyberKnife users’ meeting, CyberKnife User’s Society.

Mu Z, Fu D, Kuduvalli G (2006) Multiple fiducial identification using the hidden Markov model in imageguided radiosurgery. In: Computer vision and pattern recognition, IEEE Computer Society, p 92

Muacevic A, Staehler M, Drexler C, Wowra B, Reiser M, Tonn JC (2006) Technical description, phantomaccuracy, and clinical feasibility for fiducial-free frameless real-time image-guided spinal radiosurgery. JNeurosurg Spine 5: 303–312

Muacevic A, Drexler C, Wowra B, Schweikard A, Schlaefer A, Hoffmann RT, Wilkowski R, Winter H,Reiser M (2007) Technical description, phantom accuracy, and clinical feasibility for single-session lungradiosurgery using robotic image-guided real-time respiratory tumor tracking. Technol Cancer Res Treat6:321–328

Murphy MJ (1997) An automatic six-degree-of-freedom image registration algorithm for image-guidedframeless stereotaxic radiosurgery. Med Phys 24:857–866

Murphy MJ (2002) Fiducial-based targeting accuracy for external-beam radiotherapy. Med Phys 29:334–344

Nioutsikou E, Seppenwoolde Y, Symonds-Tayler JR, Heijmen B, Evans P, Webb S (2008) Dosimetric investigation of lung tumor motion compensation with a robotic respiratory tracking system: an experimental study. Med Phys 35:1232–1240

Reichner CA, Collins BT, Gagnon GJ, Malik S, Jamis-Dow C, Anderson ED (2005) The placement of goldfiducials for CyberKnife stereotactic radiosurgery using a modified transbronchial needle aspirationtechnique. J. Bronchol. 12:193–195

Stintzing S, Hoffmann RT, Heinemann V, Kufeld M, Muacevic A (2010) Frameless single-session roboticradiosurgery of liver metastases in colorectal cancer patients. Eur J Cancer 46:1026–1032

Van Der Voort Van Zyp NC, Prevost JB, Hoogeman MS, Praag J, Van Der Holt B, Levendag PC, VanKlaveren RJ, Pattynama P, Nuyttens JJ (2009) Stereotactic radiotherapy with real-time tumor tracking fornon-small cell lung cancer: clinical outcome. Radiother Oncol 91:296–300

Van Der Voort Van Zyp NC, Hoogeman MS, Van De Water S, Levendag PC, Van Der Holt B, Heijmen BJ,Nuyttens JJ (2010a) Clinical introduction of Monte Carlo treatment planning; a different prescription dose fornon-small cell lung cancer according to tumor location and size. Radiat Oncol 96:55–60

Vautravers-Dewas C, Dewas S, Bonodeau F, Adenis A, Lacornerie T, Penel N, Lartigau E, Mirabel X (2011)Image-guided robotic stereotactic body radiation therapy for liver metastases: is there a dose responserelationship? Int J Radiat Oncol Biol Phys 81:e39–47

Whitaker TJ, Mclaughlin M, Haile K (2009) Reducing monitor units and improving plan quality usingcombined isocentric and conformal collimators as opposed to conformal collimators along. In: CyberKnifeusers’ meeting, CyberKnife User’s Society.

Wong KH, Dieterich S, Tang J, Cleary K (2007) Quantitative measurement of CyberKnife robotic armsteering. Technol Cancer Res Treat 6:589–594

Wu X, Fu D, De La Zerda A, Bossart E, Shao H, Both J, Nikesch W, Huang Z, Markkoe A, Schwade J (2007)Patient alignment and target tracking in radiosurgery of soft-tissue tumors using combined fiducial andskeletal structures tracking techniques. In:

Urschel HC Jr, Kresl JJ, Luketich JD, Papiez L, Timmerman RD (eds) Robotic radiosurgery: treating tumorsthat move with respiration. Springer, Berlin, pp 31–36

Wu X, Dieterich S, Orton CG (2009) Point/counterpoint: only a single implanted marker is needed fortracking lung cancers for IGRT. Med Phys 36:4845–4847

Xie Y, Djajaputra D, King CR, Hossain S, Ma L, Xing L (2008) Intrafractional motion of the prostate duringhypofractionated radiotherapy. Int J Radiat Oncol Biol Phys 72:236–246.

Downloads

Published

2024-07-24

How to Cite

Fuqdan Abd Al-Yamh karim, Zaianb Hammeed Kadum, Raysan Naeem Layyad. (2024). CyberKnife System [Target Tracking/Motion Management]: Pre-Treatment Imaging, Image Fusion and Treatment Planning Technique. Clinical Images and Case Reports, 2(07), 46–55. Retrieved from https://www.visionpublisher.info/index.php/cicr/article/view/139

Issue

Section

Articles